08301 Condition Assessment and Cathodic Protection of a Reinforced Concrete Cooling Tower

Product Number: 51300-08301-SG
ISBN: 08301 2008 CP
Author: Zia Chaudhary, Fahad Mohammed Al-Mutlaq, and Ali Abdullah Al-Beed
Publication Date: 2008
$0.00
$20.00
$20.00
Investigations were conducted to assess condition and determine root cause of the ongoing concrete deterioration of the cooling tower. The beams, columns, wall panels of end walls, roof slab, bund wall, and louvers, were visually exhibiting severe concrete deterioration in many areas across the entire structure. In some areas, the concrete deterioration was very advanced and posing serious threat to integrity of the structure. Chloride had penetrated to full depth of the concrete cover in concentrations significantly higher than threshold level. Electrochemical measurements showed that the reinforcing steel was actively corroding under the sound concrete in >50% areas of the entire structure.
Investigations were conducted to assess condition and determine root cause of the ongoing concrete deterioration of the cooling tower. The beams, columns, wall panels of end walls, roof slab, bund wall, and louvers, were visually exhibiting severe concrete deterioration in many areas across the entire structure. In some areas, the concrete deterioration was very advanced and posing serious threat to integrity of the structure. Chloride had penetrated to full depth of the concrete cover in concentrations significantly higher than threshold level. Electrochemical measurements showed that the reinforcing steel was actively corroding under the sound concrete in >50% areas of the entire structure.
Product tags
Also Purchased
Picture for 03308 REHABILITATION OF REINFORCED CONCRETE
Available for download

03308 REHABILITATION OF REINFORCED CONCRETE COOLING TOWER IN PETROCHEMICAL PLANT

Product Number: 51300-03308-SG
ISBN: 03308 2003 CP
Author: Zia Chaudhary, Reyadh Al-Ibrahim
$20.00
Picture for 08317 Evaluation of Hydrophobic Concrete Coatings in Tropical Marine Environments
Available for download

08317 Evaluation of Hydrophobic Concrete Coatings in Tropical Marine Environments

Product Number: 51300-08317-SG
ISBN: 08317 2008 CP
Author: O. Rincon, Y. Hernández, V. Millano, M. Aboulhosn, C. Morales, J. Bravo, M. Sánchez, & D. Contreras
Publication Date: 2008
$20.00
Picture for 10124 Deterioration and Rehabilitation of a Newly Built Pre-Cast Reinforced Concrete Seawater
Available for download

10124 Deterioration and Rehabilitation of a Newly Built Pre-Cast Reinforced Concrete Seawater Cooling Tower

Product Number: 51300-10124-SG
ISBN: 10124 2010 CP
Author: Zia Chaudhary, Saad Awaad Al-Shehri, Fallatah Baker, Tahir Iqbal and Abduh Hakami
Publication Date: 2010
$20.00