Search
Filters
Close

08069 5,000 KM Row CP Survey Analysis and the Potential Advantages of the 100 MV Polarization Criterion for the CP of Aged Coating Oil and Gas Pipelines in Gulf and North of Mexico

Product Number: 51300-08069-SG
ISBN: 08069 2008 CP
Author: J. Canto, E. Betancourt, H. Albaya, N. Pesce, L. Escalera, H. Rivera, G. Arturo, and L. Gomez
Publication Date: 2008
$0.00
$20.00
$20.00
A survey of over 5,000 Km of pipelines was developed in 2006 to assess the CP performance of the pipelines located in the main ROWs of the Mexican States of Veracruz, Tamaulipas, Nuevo Leon, Coahuila, Durango, y Chihuahua. Historically the CP surveying in the region has been done measuring the ON potentials and applying the –850 mV criterion to these measurements. By employing a set of several satellite synchronized by GPS instrumentation, the instant OFF potentials presently reported resulted considerably more electropositive, and the compliance to the -850 mV criterion was found under 50%, in a set of over 5,000 measurements in this important region of Mexico. Besides the needs of new CP infrastructure, we report the main causes that impair the compliance of the CP to the -850 mV criterion of the NACE RP 0169 – 2002.
A survey of over 5,000 Km of pipelines was developed in 2006 to assess the CP performance of the pipelines located in the main ROWs of the Mexican States of Veracruz, Tamaulipas, Nuevo Leon, Coahuila, Durango, y Chihuahua. Historically the CP surveying in the region has been done measuring the ON potentials and applying the –850 mV criterion to these measurements. By employing a set of several satellite synchronized by GPS instrumentation, the instant OFF potentials presently reported resulted considerably more electropositive, and the compliance to the -850 mV criterion was found under 50%, in a set of over 5,000 measurements in this important region of Mexico. Besides the needs of new CP infrastructure, we report the main causes that impair the compliance of the CP to the -850 mV criterion of the NACE RP 0169 – 2002.
Product tags
Also Purchased
Picture for 08072 The Use of the 100 mV Polarization Criterion in Complex Facilities
Available for download

08072 The Use of the 100 mV Polarization Criterion in Complex Facilities

Product Number: 51300-08072-SG
ISBN: 08072 2008 CP
Author: Whitt L. Trimble
Publication Date: 2008
$20.00
Picture for 08071 Design and Construction of the Hybrid CP System for the Mexico City Airport Jet Fuel Pipeline
Available for download

08071 Design and Construction of the Hybrid CP System for the Mexico City Airport Jet Fuel Pipeline Under the 100 mV Polarization Criterion

Product Number: 51300-08071-SG
ISBN: 08071 2008 CP
Author: L. Escalera, A. Rios, H. Albaya, J. Canto, H. Carrillo, and L. Gomez
Publication Date: 2008
$20.00
Picture for 01592 100 mV POLARIZATION CRITERION AND EXTERNAL
Available for download

01592 100 mV POLARIZATION CRITERION AND EXTERNAL SCC OF UNDERGROUND PIPELINES

Product Number: 51300-01592-SG
ISBN: 01592 2001 CP
Author: J. A. Beavers and K. C. Garrity
$20.00