Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

07623 CORROSION AND INHIBITION OF 0.5% CHROMIUM STEEL

Product Number: 51300-07623-SG
ISBN: 07623 2007 CP
Author: Huey J. Chen and Yue Chen
Publication Date: 2007
$0.00
$20.00
$20.00
Corrosion behavior of 0.5% chromium steel with or without the presence of commercial inhibitors was investigated electrochemically including EIS (Electrochemical Impedance Spectroscopy) and LPR (Linear Polarization Resistance) in an aqueous CO2 environment at different temperatures and varying wall shear stresses. For comparison, the corrosion behavior of C-1018 carbon steel was also evaluated in the same test environments. The results indicated that, under the test conditions, 0.5% chromium did not improve the corrosion resistance of C-1018 carbon steel and in fact, the corrosion rate of 0.5% chromium was higher than that of the C-1018 carbon. However, the corrosion rate of 0.5% Cr steel was effectively reduced by adding 10 ppm of the commercial corrosion inhibitors tested. The effect of shear stress on inhibitor performance was not significant at the testing shear stress ranging from 36.7 to 87.4 Pa.
Corrosion behavior of 0.5% chromium steel with or without the presence of commercial inhibitors was investigated electrochemically including EIS (Electrochemical Impedance Spectroscopy) and LPR (Linear Polarization Resistance) in an aqueous CO2 environment at different temperatures and varying wall shear stresses. For comparison, the corrosion behavior of C-1018 carbon steel was also evaluated in the same test environments. The results indicated that, under the test conditions, 0.5% chromium did not improve the corrosion resistance of C-1018 carbon steel and in fact, the corrosion rate of 0.5% chromium was higher than that of the C-1018 carbon. However, the corrosion rate of 0.5% Cr steel was effectively reduced by adding 10 ppm of the commercial corrosion inhibitors tested. The effect of shear stress on inhibitor performance was not significant at the testing shear stress ranging from 36.7 to 87.4 Pa.
Product tags
Also Purchased
Picture for 07617 “I PUT IT IN, BUT WHERE DOES IT GO?” – THE FATE OF CORROSION INHIBITORS IN MULTIPHASE SYSTEMS
Available for download

07617 “I PUT IT IN, BUT WHERE DOES IT GO?” – THE FATE OF CORROSION INHIBITORS IN MULTIPHASE SYSTEMS

Product Number: 51300-07617-SG
ISBN: 07617 2007 CP
Author: David I. Horsup, J. Caleb Clark, Bernard P. Binks, Paul D.I. Fletcher, and Jake T. Hicks
Publication Date: 2007
$20.00
Picture for 07623 Corrosion and Inhibition for 0.5% Chromium Steel
Available for download

07623 Corrosion and Inhibition for 0.5% Chromium Steel

Product Number: 51300-007623-SG
ISBN: 07623 2007 CP
Author: Huey J. Chen and Yue Chen
Publication Date: 2007
$20.00
Picture for 07604 Hydrothermal Formation and Distribution of Noble Metal Particles on Type 304 SS Surface in Hig
Available for download

07604 Hydrothermal Formation and Distribution of Noble Metal Particles on Type 304 SS Surface in High Temperature Water

Product Number: 51300-07604-SG
ISBN: 07604 2007 CP
Author: Young-Jin Kim, Peter L. Andresen, Samson Hettiarachchi, and Thomas P. Diaz
Publication Date: 2007
$20.00