Integrity assessment of three pipelines in the gas transmission network (Brooks #1, Brooks #2 and
Germantown to Woodstock), using the External Corrosion Direct Assessment (ECDA) methodology in
accordance with the NACE Recommended Practice RP0502. This paper discusses the experiences of
the Integrity Management Team of the company during the application of the ECDA process, as well as
some relevant lessons learned during the implementation process.