Search
Filters
Close

03708 Computer Modeling To Predict The Magnitude of ac Voltages on Buried and Well Coated Pipelines

Product Number: 51300-03708-SG
ISBN: 03708 2003 CP
Author: Trevor C. Osborne, Dr. Alan J. Summerland
$0.00
$20.00
$20.00
The construction of new pipelines within Europe has inevitably meant the increasing use of common corridors for pipelines and overhead power transmission lines. This co-location often results in the occurrence of induced ac voltages and currents on a pipeline and, in some relatively uncommon instances, in pipeline failure. The traditional approach of installing the pipeline and then mitigating any induced ac problems after construction is no longer considered valid, due to the availability of proven, proprietary modeling software. This software, which is able to model the pipeline and power transmission line interaction conditions, and optimize mitigation design, is proving to be of significant benefit in decreasing both the safety hazard and construction costs associated with new pipelines. The software can also be used for existing pipelines. Results of modeling from a recent onshore pipeline project are presented and discussed herein. Keywords: alternating current, induced ac voltages, pylon, computer modeling
The construction of new pipelines within Europe has inevitably meant the increasing use of common corridors for pipelines and overhead power transmission lines. This co-location often results in the occurrence of induced ac voltages and currents on a pipeline and, in some relatively uncommon instances, in pipeline failure. The traditional approach of installing the pipeline and then mitigating any induced ac problems after construction is no longer considered valid, due to the availability of proven, proprietary modeling software. This software, which is able to model the pipeline and power transmission line interaction conditions, and optimize mitigation design, is proving to be of significant benefit in decreasing both the safety hazard and construction costs associated with new pipelines. The software can also be used for existing pipelines. Results of modeling from a recent onshore pipeline project are presented and discussed herein. Keywords: alternating current, induced ac voltages, pylon, computer modeling
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 98561 A REVIEW OF AC POWER LINE COUPLING
Available for download

98561 A REVIEW OF AC POWER LINE COUPLING UNTO BURIED PIPELINES

Product Number: 51300-98561-SG
ISBN: 98461 1998 CP
Author: John Dabkowski
$20.00
Picture for 03703 METHODOLOGIES FOR AC MITIGATION
Available for download

03703 METHODOLOGIES FOR AC MITIGATION

Product Number: 51300-03703-SG
ISBN: 03703 2003 CP
Author: J. Dabkowski
$20.00