03392 Application of a Time-of-Wetness (TOW) Sensor and a Thin Film Electric Resistance (TFER) Sensor for Atmospheric Corrosion Monitoring

Product Number: 51300-03392-SG
ISBN: 03392 2003 CP
Author: Sungwon Jung, Young-Geun Kim, Hong-Seok Song, SeonYeob Li, Seung-Min Lee, Young-Tai Kho
$0.00
$20.00
$20.00
In this study, a time-of-wetness (TOW) sensor was fabricated and evaluated according to wet/dry cycle. A thin film electric resistance (TFER) probe war also applied in the same environment for the measurement of corrosion rate. The TOW sensor could not differentiate the wet and dry time, especially in a corrosive environment such as 3.5% NaClsolution. This implies that wet/dry time monitoring by means of TOW sensor requires careful application in various environments. The TFER sensor produced instant atmospheric corrosion rates regardless of environment. The corrosion rate obtained by the TFER sensor could be differentiated according to wet/dry cycle, wet/dry cycle time variation and solution chemistry. Corrosion data from the TFER sensor showed that corrosion could proceed even after a wet cycle because of retained electrolyte at the surface. KEYWORDS: atmospheric corrosion, time-of-wetness, electric resistance probe, corrosion rate
In this study, a time-of-wetness (TOW) sensor was fabricated and evaluated according to wet/dry cycle. A thin film electric resistance (TFER) probe war also applied in the same environment for the measurement of corrosion rate. The TOW sensor could not differentiate the wet and dry time, especially in a corrosive environment such as 3.5% NaClsolution. This implies that wet/dry time monitoring by means of TOW sensor requires careful application in various environments. The TFER sensor produced instant atmospheric corrosion rates regardless of environment. The corrosion rate obtained by the TFER sensor could be differentiated according to wet/dry cycle, wet/dry cycle time variation and solution chemistry. Corrosion data from the TFER sensor showed that corrosion could proceed even after a wet cycle because of retained electrolyte at the surface. KEYWORDS: atmospheric corrosion, time-of-wetness, electric resistance probe, corrosion rate
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 07391 Multielectrode Penetration Sensor for Monitoring Localized and General Corrosion
Available for download

07391 Multielectrode Penetration Sensor for Monitoring Localized and General Corrosion

Product Number: 51300-07391-SG
ISBN: 07391 2007 CP
Author: Xiaodong Sun and Lie Yang
Publication Date: 2007
$20.00
Picture for 08200 Design of an Impedance Sensor for Monitoring Corrosion in Crevices
Available for download

08200 Design of an Impedance Sensor for Monitoring Corrosion in Crevices

Product Number: 51300-08200-SG
ISBN: 08200 2008 CP
Author: Robert D. Klassen and Pierre R. Roberge
Publication Date: 2008
$20.00