Search
Filters
Close

02552 CORROSION OF TITANIUM GRADE 7 IN SOLUTIONS CONTAINING FLUORIDE AND CHLORIDE SALTS

Product Number: 51300-02552-SG
ISBN: 02552 2002 CP
Author: A.L. Pulvirenti, K.M. Needham, M.A. Adel-Hadadi, A Barkatt, C.R. Marks, and J.A. Gorman
$0.00
$20.00
$20.00
The commercial alloy Titanium Grade 7 (Ti-7) was tested for both general and localized corrosion in environments containing fluoride and chloride salts. The environment was a solution designed to simulate fluoride-containing groundwater to which chloride and fluoride were added. Tests were conducted on both disks and U-bend specimens of Ti-7 in order to determine the effects of fluoride and chloride in solution under static and stressed conditions. The experiments were run over a broad range of temperatures and pH values for periods of up to 30 days. The aggressiveness of the various environments was determined primarily by the time required to observe the formation of pits using visual inspection and cross-section metallographic imaging. It was found that Titanium Grade 7 is susceptible to intergranular attack in the test solutions at moderately elevated temperatures, leading to conspicuous localized corrosion. Pit initiation was detected within 14 days, with pit depths of the order of 0.1 mm. Surface defects appeared to promote the initiation of pitting. The same environment caused a catastrophic stress corrosion cracking failure in a statically stressed U-bend.
The commercial alloy Titanium Grade 7 (Ti-7) was tested for both general and localized corrosion in environments containing fluoride and chloride salts. The environment was a solution designed to simulate fluoride-containing groundwater to which chloride and fluoride were added. Tests were conducted on both disks and U-bend specimens of Ti-7 in order to determine the effects of fluoride and chloride in solution under static and stressed conditions. The experiments were run over a broad range of temperatures and pH values for periods of up to 30 days. The aggressiveness of the various environments was determined primarily by the time required to observe the formation of pits using visual inspection and cross-section metallographic imaging. It was found that Titanium Grade 7 is susceptible to intergranular attack in the test solutions at moderately elevated temperatures, leading to conspicuous localized corrosion. Pit initiation was detected within 14 days, with pit depths of the order of 0.1 mm. Surface defects appeared to promote the initiation of pitting. The same environment caused a catastrophic stress corrosion cracking failure in a statically stressed U-bend.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 03455 DEFINING THE CORROSION PERFORMANCE WINDOW
Available for download

03455 DEFINING THE CORROSION PERFORMANCE WINDOW FOR GRADE 28 TITANIUM

Product Number: 51300-03455-SG
ISBN: 03455 2003 CP
Author: R.W. Schutz
$20.00
Picture for 03453 EFFECT OF Fe(III) LEVELS ON THE CORROSION
Available for download

03453 EFFECT OF Fe(III) LEVELS ON THE CORROSION RESISTANCE OF TITANIUM ALLOYS IN HCI SOLUTIONS

Product Number: 51300-03453-SG
ISBN: 03453 2003 CP
Author: R.L. Porter, B.J. Saldanha
$20.00