02117 COMPETITION OF AC AND DC CURRENT IN AC CORROSION UNDER CATHODIC PROTECTION

Product Number: 51300-02117-SG
ISBN: 02117 2002 CP
Author: HongSeok Song, YoungGeun Kim, SeongMin Lee, YoungTai Kho, and YoungSoo Park
$0.00
$20.00
$20.00
An alternating current (AC) corrosion on buried pipeline under cathodic protection with impressed current system has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites after the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Where pipeline was cathodically protected below –1.0V (CSE, on-potential), AC corrosion rate was affected not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and slope was 0.619 in coupon method and 0.885 in ER probe. Keywords: AC corrosion, coupon, electric resistance, cathodically protected pipeline, interference
An alternating current (AC) corrosion on buried pipeline under cathodic protection with impressed current system has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites after the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Where pipeline was cathodically protected below –1.0V (CSE, on-potential), AC corrosion rate was affected not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and slope was 0.619 in coupon method and 0.885 in ER probe. Keywords: AC corrosion, coupon, electric resistance, cathodically protected pipeline, interference
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for Requirements of Coupon AC Current Density Affecting AC Corrosion of Buried Steel Pipelines
Available for download

51315-5594-Requirements of Coupon AC Current Density Affecting AC Corrosion of Buried Steel Pipelines

Product Number: 51315-5594-SG
ISBN: 5594 2015 CP
Author: Fumio Kajiyama
Publication Date: 2015
$20.00
Picture for 98566 AC CORROSION - A NEW CHALLENGE TO
Available for download

98566 AC CORROSION - A NEW CHALLENGE TO PIPELINE INTEGRITY

Product Number: 51300-98566-SG
ISBN: 98566 1998 CP
Author: R.A. Gummow, R.G. Wakelin, SM. Segall
$20.00