01590 PIPELINE CATHODIC PROTECTION USING STEEL REFERENCE ELECTRODES

Product Number: 51300-01590-SG
ISBN: 01590 2001 CP
Author: Timothy Bieri
$0.00
$20.00
$20.00
The Colville River cathodic protection (CP) system is unique in many ways. The cased pipelines are isolated from the CP system and are directionally drilled 85 feet (26 m) below the river surface. Both thawed soils under the active channel and frozen soils under the floodplain and riverbanks characterize the crossing. These conditions make for differential thermal and soil resistivity states over time. The CP system is designed to protect the casings from external corrosion, and must function in a very dynamic and aggressive environment. Conventional reference electrodes were unsuitable for monitoring the CP system, and custom steel reference electrodes were installed. The 100 mV Polarization criterion will be used to judge the performance to the CP system. Key words: impressed current, steel anode, steel reference electrode, casing, arctic, remote monitoring, permafrost, cathodic protection, 100 mV polarization
The Colville River cathodic protection (CP) system is unique in many ways. The cased pipelines are isolated from the CP system and are directionally drilled 85 feet (26 m) below the river surface. Both thawed soils under the active channel and frozen soils under the floodplain and riverbanks characterize the crossing. These conditions make for differential thermal and soil resistivity states over time. The CP system is designed to protect the casings from external corrosion, and must function in a very dynamic and aggressive environment. Conventional reference electrodes were unsuitable for monitoring the CP system, and custom steel reference electrodes were installed. The 100 mV Polarization criterion will be used to judge the performance to the CP system. Key words: impressed current, steel anode, steel reference electrode, casing, arctic, remote monitoring, permafrost, cathodic protection, 100 mV polarization
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 98673 THE BURIED REFERENCE ELECTRODE:
Available for download

98673 THE BURIED REFERENCE ELECTRODE: A CRITICAL LONG TERM PERFORMANCE STUDY

Product Number: 51300-98673-SG
ISBN: 98673 1998 CP
Author: Taylor Leon, Wayne Geyer
$20.00
Picture for 00738 CATHODIC PROTECTION REMOTE MONITORING
Available for download

00738 CATHODIC PROTECTION REMOTE MONITORING

Product Number: 51300-00738-SG
ISBN: 00738 2000 CP
Author: Owen Sneath
$20.00
Picture for 05040 A New Permanent Reference Electrode for
Available for download

05040 A New Permanent Reference Electrode for Field Use with Cathodic Protection of Underground Pipelines and Storage Tanks

Product Number: 51300-05040-SG
ISBN: 05040 2005 CP
Author: Fengmei Song, C. Sean Brossia, Narasi Sridhar, and Darrell S. Dunn, Southwest Research Institute