01 587 BARE PIPELINES, THE 100 mV CRITERION & C.I.S. A FIELD SOLUTION TO PRACTICAL PROBLEMS

Product Number: 51300-01587-SG
ISBN: 01587 2001 CP
Author: R. Lo Pawson and R. E. McWilliams
$0.00
$20.00
$20.00
The information in this paper is based on depolarized and "on/off" close interval surveys (C.I.S.) and studies undertaken over four years, on 200 miles of bare pipelines, comprised of eighteen separate pipelines and well systems. Pipelines ranged in diameter from 6" to 20" at operating pressures of 100 to 800 p.s.i. On bare pipelines, it can be very difficult to achieve a polarized off potential of -850 millivolts or more negative for the length of the pipeline, due to the high current requirements, poor current distribution, varying soil resistivities and many other factors. The cathodic protection system required to achieve the -850 millivolt criterion, will be costly to operate, maintain and monitor. Successful application of the 100 millivolt polarization criterion can achieve the desired protection level at reduced current requirements, a lower level of foreign structure interference and lower installation and operating costs. Key Words: cathodic protection, cathodic protection criteria, depolarization, depolarized potential, 100 millivolt criterion, close interval survey, bare pipelines, pipe to soil potential, potential survey graphs.
The information in this paper is based on depolarized and "on/off" close interval surveys (C.I.S.) and studies undertaken over four years, on 200 miles of bare pipelines, comprised of eighteen separate pipelines and well systems. Pipelines ranged in diameter from 6" to 20" at operating pressures of 100 to 800 p.s.i. On bare pipelines, it can be very difficult to achieve a polarized off potential of -850 millivolts or more negative for the length of the pipeline, due to the high current requirements, poor current distribution, varying soil resistivities and many other factors. The cathodic protection system required to achieve the -850 millivolt criterion, will be costly to operate, maintain and monitor. Successful application of the 100 millivolt polarization criterion can achieve the desired protection level at reduced current requirements, a lower level of foreign structure interference and lower installation and operating costs. Key Words: cathodic protection, cathodic protection criteria, depolarization, depolarized potential, 100 millivolt criterion, close interval survey, bare pipelines, pipe to soil potential, potential survey graphs.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 01584 APPLYING THE 100 MILLIVOLT POLARIZATION
Available for download

01584 APPLYING THE 100 MILLIVOLT POLARIZATION CRITERION TO OLDER AND BARE OR INEFFECTIVELY COATED TRANSMISSION PIPELINES

Product Number: 51300-01584-SG
ISBN: 01584 2001 CP
Author: Jeffrey L. Didas
$20.00
Picture for 01581 ORIGIN AND VALIDATION OF THE 100 mV
Available for download

01581 ORIGIN AND VALIDATION OF THE 100 mV POLARIZATION CRITERION

Product Number: 51300-01581-SG
ISBN: 01581 2001 CP
Author: Thomas J. Barlo
$20.00
Picture for 01592 100 mV POLARIZATION CRITERION AND EXTERNAL
Available for download

01592 100 mV POLARIZATION CRITERION AND EXTERNAL SCC OF UNDERGROUND PIPELINES

Product Number: 51300-01592-SG
ISBN: 01592 2001 CP
Author: J. A. Beavers and K. C. Garrity
$20.00