01480 ON-BOARD HYPOCHLORITE GENERATION FOR BIOFOULING CONTROL

Product Number: 51300-01480-SG
ISBN: 01480 2001 CP
Author: B. Zwicker, J. Porter, G. Pelletier, R.D. Klassen and P.R. Roberge
$0.00
$20.00
$20.00
Biofouling within the cooling water systems of ships can be serious enough to cause immobilization. Marine growth on pipes also promotes crevice corrosion. In seawater, blue mussels are the predominate species that cause biofouling. A biofouling test system was constructed at the Dockyard Laboratory in Halifax, Nova Scotia by the Defense Research Establishment Atlantic. Seawater from the Halifax harbor continuously flowed through pipe networks that were designed to simulate the cooling water piping on a ship. Three commercial chemical injection systems were tested simultaneously, namely copper, iodine and hypochlorite. Personnel from the Bedford Institute of Oceanography assessed the biological effectiveness of each system by observing adult mussels one at a time in a beaker of treated water. These tests revealed a wide range of effectiveness between these chemicals in preventing mussel attachment. Each injection system was better than no treatment at all. As designed and operated, the copper and iodine release systems were only modestly effective whereas the hypochlorite system was completely effective in preventing mussel attachment. Observations of the piping after several months of flow-through operation were consistent with the biological tests with treated water. The process engineering for installing a hypochlorite system on a ship is described. Keywords: anti biofouling agents, mussels, copper, iodine, hypochlorite
Biofouling within the cooling water systems of ships can be serious enough to cause immobilization. Marine growth on pipes also promotes crevice corrosion. In seawater, blue mussels are the predominate species that cause biofouling. A biofouling test system was constructed at the Dockyard Laboratory in Halifax, Nova Scotia by the Defense Research Establishment Atlantic. Seawater from the Halifax harbor continuously flowed through pipe networks that were designed to simulate the cooling water piping on a ship. Three commercial chemical injection systems were tested simultaneously, namely copper, iodine and hypochlorite. Personnel from the Bedford Institute of Oceanography assessed the biological effectiveness of each system by observing adult mussels one at a time in a beaker of treated water. These tests revealed a wide range of effectiveness between these chemicals in preventing mussel attachment. Each injection system was better than no treatment at all. As designed and operated, the copper and iodine release systems were only modestly effective whereas the hypochlorite system was completely effective in preventing mussel attachment. Observations of the piping after several months of flow-through operation were consistent with the biological tests with treated water. The process engineering for installing a hypochlorite system on a ship is described. Keywords: anti biofouling agents, mussels, copper, iodine, hypochlorite
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 01414 ADVANCES IN MATERIALS FOR SODIUM
Available for download

01414 ADVANCES IN MATERIALS FOR SODIUM HYPOCHLORITE SERVICE

Product Number: 51300-01414-SG
ISBN: 01414 2001 CCP
Author: Steve Drake
$20.00
Picture for 08251 Laboratory Testing of Seawater at Elevated Temperatures With Low Concentrations of Hypochlorit
Available for download

08251 Laboratory Testing of Seawater at Elevated Temperatures With Low Concentrations of Hypochlorite

Product Number: 51300-08251-SG
ISBN: 08251 2008 CP
Author: Sarah Standlee, Killian Efird, and Katherine May
Publication Date: 2008
$20.00
Picture for 08524 What is the Best Resin for FRP Sodium Hypochlorite Storage Tanks?
Available for download

08524 What is the Best Resin for FRP Sodium Hypochlorite Storage Tanks?

Product Number: 51300-08524-SG
ISBN: 08524 2008 CP
Author: Michael G. Stevens
Publication Date: 2008
$20.00