01063 INFLUENCE OF TURBULENT FLOW ON THE LOCALISED CORROSION PROCESSES OF MILD STEEL WITH INHIBITED AQUEOUS CO2 SYSTEMS

Product Number: 51300-01063-SG
ISBN: 01063 2001 CP
Author: J.L. Mora-Mendoza & S. Turgoose
$0.00
$20.00
$20.00
CO2 saturated solutions of 3% NaCl were used to study the corrosion inhibition of mild steel samples under turbulent flow conditions at different pH values. The performance of cetyl trimethyl ammonium bromide (CTAB) was tested with three different concentrations (20, 60 and 100 ppm) and three different pHs (3.8, 5 and 6). The rotating cylinder electrode (RCE) was used to test different turbulent flow conditions (1000 - 5000 rpm). It was found that the inhibitor performance is function of its concentration and pH. A localised corrosion process was found on the surthce examination and a further research was carried out to determine its causes. It was demonstrated with the use of cyclic anodic polarisation curves and surface examinations that the localised corrosion process does not occur at a specific rotation speed. With the use of potentiostatic experiments, the effect of shear stress and the instantaneous changes in Ecorr observed when the rotation speed was increased were simulated. The electrochemical measurements and the surface examinations, showed that the changes in Ecorr to more positive values are more important in producing the localised process, and removing the electrostatically adsorbed inhibitor from the surface sample, than increases in shear stress. Key words: CO2 corrosion, turbulent flow, localised corrosion, inhibitors, electrochemistry.
CO2 saturated solutions of 3% NaCl were used to study the corrosion inhibition of mild steel samples under turbulent flow conditions at different pH values. The performance of cetyl trimethyl ammonium bromide (CTAB) was tested with three different concentrations (20, 60 and 100 ppm) and three different pHs (3.8, 5 and 6). The rotating cylinder electrode (RCE) was used to test different turbulent flow conditions (1000 - 5000 rpm). It was found that the inhibitor performance is function of its concentration and pH. A localised corrosion process was found on the surthce examination and a further research was carried out to determine its causes. It was demonstrated with the use of cyclic anodic polarisation curves and surface examinations that the localised corrosion process does not occur at a specific rotation speed. With the use of potentiostatic experiments, the effect of shear stress and the instantaneous changes in Ecorr observed when the rotation speed was increased were simulated. The electrochemical measurements and the surface examinations, showed that the changes in Ecorr to more positive values are more important in producing the localised process, and removing the electrostatically adsorbed inhibitor from the surface sample, than increases in shear stress. Key words: CO2 corrosion, turbulent flow, localised corrosion, inhibitors, electrochemistry.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 01042 MATERIAL SELECTION FOR SEPARATION,
Available for download

01042 MATERIAL SELECTION FOR SEPARATION, TRANSPORTATION AND DISPOSAL OF CO2

Product Number: 51300-01042-SG
ISBN: 01042 2001 CP
Author: Marion Seiersten
$20.00
Picture for 01060 EVALUATION OF CORROSION INHIBITORS
Available for download

01060 EVALUATION OF CORROSION INHIBITORS FOR CO2 CORROSION USING ELECTROCHEMICAL AND NON- ELECTROCHEMICAL TECHNIQUES

Product Number: 51300-01060-SG
ISBN: 01060 2001 CP
Author: Dharma Abayarathna, Ali Naraghi
$20.00
Picture for 01057 CORROSION MONITORING AS A MEANS
Available for download

01057 CORROSION MONITORING AS A MEANS OF EFFECTING CONTROL OF CO2 CORROSION

Product Number: 51300-01057-SG
ISBN: 01057 2001 CP
Author: D.A. Eden and A. Etheridge
$20.00