Search
Filters
Close

01025 HIGH TEMPERATURE AND HIGH FLOW VELOCITY TESTS FOR CO2 CORROSION INHIBITORS

Product Number: 51300-01025-SG
ISBN: 01025 2001 CP
Author: J. Kvarekval and E. Gulbrandsen
$0.00
$20.00
$20.00
The performance of various corrosion inhibitors has been tested in flow loop at high temperature and high flow velocity. The experimental conditions were 60-150°C, 1 bar CO2, pH 5 and 0.1-1% NaCl. The flow velocity was varied between 1 and 9 m/s, corresponding to wall shear stress values between 5 and 135 Pa respectively. The general observation was that changes in flow velocities had negligible effect on the inhibited corrosion rate. No inhibition failure related to flow was observed. As corrosion product layers formed on the specimens, separating the contributions of inhibitor and corrosion product film with respect to protective effect became difficult. A test of flow sensitivity under film forming conditions may reflect the flow persistency of the corrosion product films rather than that of the inhibitor. It was found that temperature is a critical parameter for the tested inhibitors. The inhibited corrosion rate generally increased with increasing temperature. The effect of temperature was dependent on the inhibitor formulation. Keywords: CO2 corrosion, corrosion inhibitors, corrosion testing, high temperature, flow velocity
The performance of various corrosion inhibitors has been tested in flow loop at high temperature and high flow velocity. The experimental conditions were 60-150°C, 1 bar CO2, pH 5 and 0.1-1% NaCl. The flow velocity was varied between 1 and 9 m/s, corresponding to wall shear stress values between 5 and 135 Pa respectively. The general observation was that changes in flow velocities had negligible effect on the inhibited corrosion rate. No inhibition failure related to flow was observed. As corrosion product layers formed on the specimens, separating the contributions of inhibitor and corrosion product film with respect to protective effect became difficult. A test of flow sensitivity under film forming conditions may reflect the flow persistency of the corrosion product films rather than that of the inhibitor. It was found that temperature is a critical parameter for the tested inhibitors. The inhibited corrosion rate generally increased with increasing temperature. The effect of temperature was dependent on the inhibitor formulation. Keywords: CO2 corrosion, corrosion inhibitors, corrosion testing, high temperature, flow velocity
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 01017 ALLOYED 13% CHROMIUM STEEL UNS S41427
Available for download
Picture for 01029 INHIBITION OF CO2 CORROSION IN
Available for download

01029 INHIBITION OF CO2 CORROSION IN MULTIPHASE FLOW AND SOLIDS PRODUCTION A CASE HISTORY

Product Number: 51300-01029-SG
ISBN: 01029 2001 CP
Author: Roger W Kidder, Syamsudin, James P Smith and Ian H Gilbert
$20.00
Picture for 01005 ESTABLISHMENT OF CORROSION INHIBITOR
Available for download

01005 ESTABLISHMENT OF CORROSION INHIBITOR PERFORMANCE IN DEEPWATER CONDITIONS

Product Number: 51300-01005-SG
ISBN: 01005 2001 CP
Author: L.A. Skogsberg, B.P. Miglin, S. Ramachandran and K.A. Bartrip
$20.00