Search
Filters
Close

00664 ON-LINE SILICA MEASUREMENT FOR STEAM GENERATING SYSTEMS

Product Number: 51300-00644-SG
ISBN: 00664 2000 CP
Author: K. Anthony Selby
$0.00
$20.00
$20.00
Asbestos cement (AC) piping has been used for potable water, irrigation, drainage and sewer systems for approximately 100 years. The most significant problem affecting the structural integrity of asbestos cement pipes results from the leaching of the cement mortar binder out of the pipe wall. This leaching can occur from the internal surface, depending on the chemical make-up of the water or sewage, or from the external surface, depending on the aggressiveness of the groundwater and soil conditions. This paper describes the findings of test work on AC piping samples from potable water and sewer piping that have been in service for up to 40 to 50 years, and discusses an empirical equation developed by our company to estimate the remaining service life of AC piping systems.
Asbestos cement (AC) piping has been used for potable water, irrigation, drainage and sewer systems for approximately 100 years. The most significant problem affecting the structural integrity of asbestos cement pipes results from the leaching of the cement mortar binder out of the pipe wall. This leaching can occur from the internal surface, depending on the chemical make-up of the water or sewage, or from the external surface, depending on the aggressiveness of the groundwater and soil conditions. This paper describes the findings of test work on AC piping samples from potable water and sewer piping that have been in service for up to 40 to 50 years, and discusses an empirical equation developed by our company to estimate the remaining service life of AC piping systems.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 00665 ON-LINE pH MEASUREMENT FOR STEAM
Available for download

00665 ON-LINE pH MEASUREMENT FOR STEAM GENERATING SYSTEMS

Product Number: 51300-00665-SG
ISBN: 00665 2000 CP
Author: David M. Gray, Charles J. McDonough
$20.00
Picture for 00678 Using Surface Scanning Techniques for
Available for download

00678 Using Surface Scanning Techniques for Investigating the Activation Process for Indium Activated, Aluminum Alloy Sacrificial Anodes

Product Number: 51300-00678-SG
ISBN: 00678 2000 CP
Author: John N. Murray, Douglas C. Hansen, Robert A. Brizzolara
$20.00
Picture for 00673 A NOVEL APPROACH TO CATHODIC PROTECTION
Available for download

00673 A NOVEL APPROACH TO CATHODIC PROTECTION DESIGN FOR MARINE PIPELINES: PART I - AN INCLUSIVE ATTENUATION EQUATION

Product Number: 51300-00673-SG
ISBN: 00673 2000 CP
Author: Patrick Pierson, Keith P. Bethune, William H. Hartt, and Palaniswam Anathakrishnan
$20.00