00330 SCALE INHIBITOR EVALUATION FOR AN EFFLUENT INJECTION SYSTEM IN WEST KUWAIT

Product Number: 51300-00330-SG
ISBN: 00330 2000 CP
Author: A. Al-Hashem, M. Salman and K. Al-Muhanna
$0.00
$20.00
$20.00
Six scale inhibitors were evaluated to reduce the scaling tendency of an effluent water produced from the western zone of the Kuwait Oil Fields, commingled with three different formation waters. The effluent water to formation water ratios for each of the water combinations under study were chosen to reflect worst case conditions, as predicted from a computer compatibility study. In this study, static autoclave jar tests were conducted prior to dynamic scaling tests in order to select an appropriate dose concentration for the inhibitors. All scale inhibitors were tested under reservoir conditions at a fixed dose of 15 ppm. The results of the static autoclave jar test and the dynamic scaling test indicated that the most effective scale inhibitor was an aqueous solution of organic phosphates at an optimum dose rates of 15 and 20 ppm, respectively for CaCO3 and BaSO4 scales. Keywords: scaling, autoclave, jar test, dynamic scale testing, effluent water, formation waters.
Six scale inhibitors were evaluated to reduce the scaling tendency of an effluent water produced from the western zone of the Kuwait Oil Fields, commingled with three different formation waters. The effluent water to formation water ratios for each of the water combinations under study were chosen to reflect worst case conditions, as predicted from a computer compatibility study. In this study, static autoclave jar tests were conducted prior to dynamic scaling tests in order to select an appropriate dose concentration for the inhibitors. All scale inhibitors were tested under reservoir conditions at a fixed dose of 15 ppm. The results of the static autoclave jar test and the dynamic scaling test indicated that the most effective scale inhibitor was an aqueous solution of organic phosphates at an optimum dose rates of 15 and 20 ppm, respectively for CaCO3 and BaSO4 scales. Keywords: scaling, autoclave, jar test, dynamic scale testing, effluent water, formation waters.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 00332 Recent Trends In Cooling Water
Available for download

00332 Recent Trends In Cooling Water lnhibitors

Product Number: 51300-00332-SG
ISBN: 00332 2000 CP
Author: M A Quraishi, I.H.Farooqi and P.A.Saini
$20.00
Picture for 00327 THE PERFORMANCE OF NEW VOLATILE
Available for download

00327 THE PERFORMANCE OF NEW VOLATILE OXYGEN SCAVENGER AND ITS FIELD APPLICATION IN BOILER SYSTEMS

Product Number: 51300-00327-SG
ISBN: 00327 2000 CP
Author: Y. Shimura, K. Uchida, T. Sato and S. Taya
$20.00
Picture for 00338 Further Advances in the Development of
Available for download

00338 Further Advances in the Development of Environmentally Friendly Corrosion Inhibitors for the Oilfield

Product Number: 51300-00338-SG
ISBN: 00338 2000 CP
Author: Mark Gough
$20.00