At the entrance of the Muscar plant, in the northern part of Monagas State in Venezuela, a flow loop was constructed in 1993 to perform corrosion tests in real dynamic conditions, using flush mounted disc probes. This loop consists of a 50 m length - 0.8 m OD pipeline whose inlet and outlet pressures are 8273 kPa and 3400 kPa respectively, permitting a gas flow of ...
Keywords: asphaltene, dynamic conditions, RCE, carbon dioxide, hydrogen sulfide