99593 LOCALISED CORROSION TESTING OF CRA MATERIALS IN ELEVATED TEMPERATURE SOUR GAS ENVIRONMENTS

Product Number: 51300-99593-SG
ISBN: 99593 1999 CP
Author: Mohammed A1-Maslamani, Peter Felton and John W Oldfield
$0.00
$20.00
$20.00
An exposure test programme has been undertaken to investigate the localised corrosion resistance of Alloys 28, 825, G3 and 625 in two simulated sour gas environments at 150°C. The chloride levels in these test environments, containing 30 psi (0.21 MPa) H2S and 101 psi (0.70 MPa) CO2, were 150 ppm and 30,000 ppm. The general corrosion rate of each material was found to be negligible in each test. Alloy 825 alone was susceptible to minor pitting and crevice initiation in the 150 ppm chloride environment. Increasing the chloride level to 30,000 ppm resulted in more severe crevice attack of Alloy 825 and crevice corrosion of Alloy 28. Alloys G3 and 625 were not susceptible to localised corrosion in either test environment. The exposure tests were supported by complementary electrochemical polarisation curves in the low chloride environment. The curves did not exhibit clearly defined passive regions, which were masked by additional anodic current from the oxidation of H2S. Keywords: sour gas, corrosion resistant alloys, pitting, crevice corrosion, electrochemical testing
An exposure test programme has been undertaken to investigate the localised corrosion resistance of Alloys 28, 825, G3 and 625 in two simulated sour gas environments at 150°C. The chloride levels in these test environments, containing 30 psi (0.21 MPa) H2S and 101 psi (0.70 MPa) CO2, were 150 ppm and 30,000 ppm. The general corrosion rate of each material was found to be negligible in each test. Alloy 825 alone was susceptible to minor pitting and crevice initiation in the 150 ppm chloride environment. Increasing the chloride level to 30,000 ppm resulted in more severe crevice attack of Alloy 825 and crevice corrosion of Alloy 28. Alloys G3 and 625 were not susceptible to localised corrosion in either test environment. The exposure tests were supported by complementary electrochemical polarisation curves in the low chloride environment. The curves did not exhibit clearly defined passive regions, which were masked by additional anodic current from the oxidation of H2S. Keywords: sour gas, corrosion resistant alloys, pitting, crevice corrosion, electrochemical testing
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 06158 INVESTIGATION OF INTERGRANULAR CORROSION
Available for download

06158 INVESTIGATION OF INTERGRANULAR CORROSION OF Alloy 825 IN SOUR SERVICE

Product Number: 51300-06158-SG
ISBN: 06158 2006 CP
Author: Daryoush Masouri, Mehrdad Arastoo, Mahmoud Zafari
$20.00