Search
Filters
Close

07311 THE INFLUENCE OF STEEL MICROSTRUCTURE, CHEMICAL COMPOSITION AND PRECORROSION ON CO2 CORROSION INHIBITOR EFFICIENCY

Product Number: 51300-07311-SG
ISBN: 07311 2007 CP
Author: L. D. Paolinelli, T. Pérez, and S. N. Simison
Publication Date: 2007
$0.00
$20.00
$20.00
The influence of steel microstructure, pre-corrosion period and 1 %Cr content addition on CO2 corrosion susceptibility of C-Mn steels and on the inhibitor performance has been studied. In a previous paper, we have shown that the addition of 1 %Cr has a remarkable detrimental effect on inhibitor performance1. Two carbon steels with two different microstructures (annealed, and quenched and tempered (Q&T)) were tested in a deoxygenated 5% wt. NaCl solution, saturated with CO2 at 40 °C, pH 6. The performance of a commercial imidazoline-based product to control CO2 corrosion was studied by means of electrochemical measurements employing a.c. and d.c. techniques. The inhibitor was added after 24 hrs pre-corrosion period or before electrode immersion (no pre-corrosion). Surface film characteristics were studied by means of SEM and EDX. The results show the detrimental effect of pre-corrosion and Cr addition on inhibitor efficiency. It is also shown that the pre-corrosion impact depends on microstructure and chemical composition.
The influence of steel microstructure, pre-corrosion period and 1 %Cr content addition on CO2 corrosion susceptibility of C-Mn steels and on the inhibitor performance has been studied. In a previous paper, we have shown that the addition of 1 %Cr has a remarkable detrimental effect on inhibitor performance1. Two carbon steels with two different microstructures (annealed, and quenched and tempered (Q&T)) were tested in a deoxygenated 5% wt. NaCl solution, saturated with CO2 at 40 °C, pH 6. The performance of a commercial imidazoline-based product to control CO2 corrosion was studied by means of electrochemical measurements employing a.c. and d.c. techniques. The inhibitor was added after 24 hrs pre-corrosion period or before electrode immersion (no pre-corrosion). Surface film characteristics were studied by means of SEM and EDX. The results show the detrimental effect of pre-corrosion and Cr addition on inhibitor efficiency. It is also shown that the pre-corrosion impact depends on microstructure and chemical composition.
Product tags
Also Purchased
Picture for 07319 EFFECT OF ORGANIC ACIDS IN CO2 CORROSION
Available for download

07319 EFFECT OF ORGANIC ACIDS IN CO2 CORROSION

Product Number: 51300-07319-SG
ISBN: 07319 2007 CP
Author: Vanessa Fajardo, Christian Canto, Bruce Brown, and Srdjan Nesic
Publication Date: 2007
$20.00
Picture for 11062 Corrosion Inhibitor Efficiency Limits and Key Factors
Available for download

11062 Corrosion Inhibitor Efficiency Limits and Key Factors

Product Number: 51300-11062-SG
ISBN: 11062 2011 CP
Author: Alan Crossland, Jose Vera, Richard C. Woollam, Stephen Turgoose, James Palmer and Gareth John
Publication Date: 2011
$20.00
Picture for 07317 CORROSION CONTROL IN THE OIL AND GAS PRODUCTION – 5 SUCCESSFUL CASE HISTORIES
Available for download

07317 CORROSION CONTROL IN THE OIL AND GAS PRODUCTION – 5 SUCCESSFUL CASE HISTORIES

Product Number: 51300-07317-SG
ISBN: 07317 2007 CP
Author: Markus Oberndorfer, Karin Thayer, and Wolfgang Havlik
Publication Date: 2007
$20.00