Search
Filters
Close

Individual Conference Papers

View as
Sort by
Display per page
Picture for The Development of Sulfur Solvent/Corrosion Inhibitor Product for Extremely Aggressive Sour Environm
Available for download

The Development of Sulfur Solvent/Corrosion Inhibitor Product for Extremely Aggressive Sour Environm

Product Number: 51316-7783-SG
ISBN: 7783 2016 CP
Author: Haitao Fang
Publication Date: 2016
$20.00
The Downfalls of Coating Specifications
Available for download
Picture for The Effect of Different Polyaniline Types in Silicon Dioxide Containing Coatings for Carbon Steel Protection in Artificial Geothermal Brines
Available for download

The Effect of Different Polyaniline Types in Silicon Dioxide Containing Coatings for Carbon Steel Protection in Artificial Geothermal Brines

Product Number: 51319-13121-SG
Author: Gabriela Aristia
Publication Date: 2019
$20.00
Picture for The Effect of H2S Consumption on SSC Susceptibility of High Strength Wire Grades for Flexible Pipes
Available for download

The Effect of H2S Consumption on SSC Susceptibility of High Strength Wire Grades for Flexible Pipes

Product Number: 51319-13483-SG
Author: Merlin Bandeira
Publication Date: 2019
$20.00

Flexible pipes are widely used in offshore installations especially in Brazil to produce and export oil and gas. In order to guarantee safety operation in pre-salt fields without super estimate the field corrosiveness many efforts are dedicate to study the actual H2S concentration in the pipe annulus. The data presented in the literature point to a considerably lower H2S concentrations than those predicted based on traditional annulus permeation models. The consequences of these studies have direct impact on flexible pipes design suggesting the possibility to use lighter lower cost with good performance structures. However to specify correctly the armor wires is crucial to evaluate the corrosion resistance on annulus condition especially the stress corrosion cracking. The present study goal is to evaluate the corrosion performance of a range of flexible pipes armor wires considering susceptibility of SCC and HIC on laboratory simulated annulus condition. The laboratory tests were conceived to measure and compare pH H2S and Fe2+ concentration during the whole test period. The H2S flowrate was constant at 4 mL/min. All experiments were carried out at 30 oC 0.1 MPa using a gas mixture with 1% H2S in CO2. It was also controlled the ratio of liquid phase (synthetic seawater) and steel surface area (0.7 mL/cm2). The studied flow rate was 10-6 mL/min/cm2. A blank test without steel wires revealed that pH was stable at 4.9 and the maximal H2S concentration recorded was 20 ppm both after 150 h of test. On test simulating the annulus condition the pH was around 6.1 from 20 h of immersion until the end of the test (2000 h). The H2S concentration was always lower than 1 ppm and the Fe2+ concentration increased with immersion time up to 1200 ppm. Among the three high strength wire grades tested by four point bend test only one was susceptible to SCC under the conditions tested. Further studies will be presented concerning the HIC and microstructure influence on corrosion performance. The aim of this test program is to provide technical data to support future modifications on flexible pipe design with guarantee of good corrosion performance of armor wires.