97118 CORROSION OF CARBON STEEL IN SATURATED HIGH-LEVEL WASTE SALT SOLUTIONS

Product Number: 51300-97118-SG
ISBN: 97118 1997 CP
Author: B. J. Wiersrna, W. R. Parish
$0.00
$20.00
$20.00
High level waste stored as crystallized salts is to be removed from carbon stce.1tanks by water dissolution. Dissolution of the saltcake must be performed in a manner which will not impact the integrity of the tank. Corrosion testing was performed to determine the amount of corrosion inhibitor that must be added to the dissolution water in order to ensure that the salt solution fortned would not induce corrosion degradation of the tank materials. The corrosion testing performed included controlled potential slow strain rate, coupon immersion, and potentic dynamic polmization tests. These tests were utilized to investigate the susceptibility of the cooling coil material to stress corrosion cracking in the anticipated environments. No evidence of SCC was observed in any of the tests. Based on these results, the recommended corrosion requirements were that the temperature of the salt solution be less than 50 °C and that the minimum hydroxide concentration be 0.4 molar. It was also recommended that the hydroxide concentration not stay below 0.4 molar for longer than 45 days. Keywords: Stress Corrosion Cracking, Radioactive Waste, Slow Strain Rate Tests
High level waste stored as crystallized salts is to be removed from carbon stce.1tanks by water dissolution. Dissolution of the saltcake must be performed in a manner which will not impact the integrity of the tank. Corrosion testing was performed to determine the amount of corrosion inhibitor that must be added to the dissolution water in order to ensure that the salt solution fortned would not induce corrosion degradation of the tank materials. The corrosion testing performed included controlled potential slow strain rate, coupon immersion, and potentic dynamic polmization tests. These tests were utilized to investigate the susceptibility of the cooling coil material to stress corrosion cracking in the anticipated environments. No evidence of SCC was observed in any of the tests. Based on these results, the recommended corrosion requirements were that the temperature of the salt solution be less than 50 °C and that the minimum hydroxide concentration be 0.4 molar. It was also recommended that the hydroxide concentration not stay below 0.4 molar for longer than 45 days. Keywords: Stress Corrosion Cracking, Radioactive Waste, Slow Strain Rate Tests
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 97129 COUPON CORROSION MONITORING OF A
Available for download

97129 COUPON CORROSION MONITORING OF A HIGH LEVEL WASTE TANK

Product Number: 51300-97129-SG
ISBN: 97129 1997 CP
Author: J. I. Mickalonis
$20.00
Picture for 97088 EROSION/CORROSION CONCERNS IN FEED
Available for download

97088 EROSION/CORROSION CONCERNS IN FEED PREPARATION SYSTEMS AT THE DEFENSE WASTE PROCESSING FACILITY

Product Number: 51300-97088-SG
ISBN: 97088 1997 CP
Author: J. T. Gee, G. T. Chandles, W.L. Daugherty, K J. Imrich, C. F. Jenkins
$20.00
Picture for 97119 LABORATORY SIMULATION OF SALT
Available for download

97119 LABORATORY SIMULATION OF SALT DISSOLUTION DURING WASTE REMOVAL

Product Number: 51300-97119-SG
ISBN: 97119 1997 CP
Author: B. J. Wlersma, W. R. Parish
$20.00