Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.
During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.
Use GIVING24 at checkout to save 20% on eCourses and books (some exclusions apply)!
An indirect impedance technique is assessed as a possible method to detect corrosion within external post-tensioned bridge tendons. The method aims to extract the impedance of the steel-grout interface from the impedance measured at the surface of the grout.
An indirect impedance technique is assessed as a possible method to detect corrosion within external post-tensioned bridge tendons. The indirect impedance aims to extract the impedance of the steel-grout interface from the impedance measured at the surface of the grout. However, the electrode configuration required for the indirect impedance measurement yields geometry-induced frequency dispersion that confounds interpretation. A proof of concept was established for using indirect impedance to detect corrosion in post-tensioned tendons. Bench-top experiments were performed to show that the indirect impedance was sensitive to the properties of the steel and grout interface. Finite-element models were used to simulate the indirect impedance and determine how the geometry of the unusual electrode configuration influences the impedance. The indirect impedance was able to distinguish between locations of corroding steel and locations of passive steel, even if the actual damage to the steel was minimal. However, the complex nature of the grout impedance limits the indirect impedance measurement to providing only a qualitative assessment of the corrosion of bridge tendons.
Key words: Impedance, Corrosion Detection
A portable electrochemical noise measuring device has recently been developed to evaluate the corrosion-protective properties of anti-corrosive coatings in-service.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
Details of a second procedure developed by the testing centre INNCOA to assess the performance of several insulation systems with respect to the ingress of water vapour through a damaged section of the covering layer.
Two drilling mud samples, taken at different HDD operations. Results demonstrated the presence of microorganism populations associated with microbiologically influenced corrosion (MIC) at one of the two test locations.