Search
Filters
Close

Celebrate World Corrosion Awareness Day with 20% off eCourses and eBooks with code WCAD2024 at checkout!

51312-01444-Finding a Solution for Designing an Optimum Cathodic Protection System for an Existing Tank Farm

Product Number: 51312-01444-SG
ISBN: 01444 2012 CP
Author: Mohsen Khosravi
Publication Date: 2012
$0.00
$20.00
$20.00
Many existing small fuel tank farms still have not cathodic protection. New revised environment and safety standards force the operator to install cathodic protection for their system. Limited owned expensive land from one hand neighbor metallic underground piping such as fire fighting water which can interfere with CP system from other hand are challenging problem in this field. As the current and potential distribution tests are not possible due to lack of any permanent reference electrode beneath the tank bottom plate and also horizontal or angel drilling is not economically feasible for these small tank farms utilizing the boundary element method (BEM) the important factor for a cathodic protection system such as type of ground bed semi deep deep distributed anodes around the tank's perimeter and concentrated surface ground bed the location of the ground bed and optimum current that can polarizes the surface potential to protection potential have been simulated for tank bottom plate in contact with soil and neighbor under ground piping. Then the results were illustrated in some graphs that showing the potential distribution in tank bottom and pipe's surface. The results show appropriate performance of semi deep ground bed from potential distribution and economical point of view. Finally the best anodic current and location of anodes was found by simulated model too.
Many existing small fuel tank farms still have not cathodic protection. New revised environment and safety standards force the operator to install cathodic protection for their system. Limited owned expensive land from one hand neighbor metallic underground piping such as fire fighting water which can interfere with CP system from other hand are challenging problem in this field. As the current and potential distribution tests are not possible due to lack of any permanent reference electrode beneath the tank bottom plate and also horizontal or angel drilling is not economically feasible for these small tank farms utilizing the boundary element method (BEM) the important factor for a cathodic protection system such as type of ground bed semi deep deep distributed anodes around the tank's perimeter and concentrated surface ground bed the location of the ground bed and optimum current that can polarizes the surface potential to protection potential have been simulated for tank bottom plate in contact with soil and neighbor under ground piping. Then the results were illustrated in some graphs that showing the potential distribution in tank bottom and pipe's surface. The results show appropriate performance of semi deep ground bed from potential distribution and economical point of view. Finally the best anodic current and location of anodes was found by simulated model too.
Product tags
Also Purchased
Picture for 08058 Prevention of External (Soil Side) Corrosion on Storage Tank Bottom Plates by Cathodic Protect
Available for download

08058 Prevention of External (Soil Side) Corrosion on Storage Tank Bottom Plates by Cathodic Protection System

Product Number: 51300-08058-SG
ISBN: 08058 2008 CP
Author: Bipradas Chatterjee
Publication Date: 2008
$20.00
Picture for 02107 Using Coupons to Monitor the Effectiveness of Tank Bottom Cathodic Protection
Available for download

02107 Using Coupons to Monitor the Effectiveness of Tank Bottom Cathodic Protection

Product Number: 51300-02107-SG
ISBN: 02107 2002 CP
Author: Paul R. Nichols, Deyuan Fan, and Alvin D. Goolsby
$20.00