Search
Filters
Close

51316-7712-Anodic Behavior of SteeI in Enhanced Sulfate Solutions

Product Number: 51316-7712-SG
ISBN: 7712 2016 CP
Author: Kingsley Lau
Publication Date: 2016
$0.00
$20.00
$20.00
Severe corrosion of post-tensioned tendons in Florida bridges utilizing pre-packaged thixotropic grout products were documented. In those cases conventional causes of steel corrosion in tendons were not consistent with corrosion development. Good correlation between the presence of deficient grout corrosion development and enhanced sulfate ion concentrations was observed. An update on laboratory testing of steel wire in sulfate solutions representative of deficient grout pore water is presented. The test setup was made to determine if sulfates in alkaline solutions can depassivate steel or if early presence of sulfates in alkaline solution may provide conditions that would adversely affect stable passive film formation. In the open circuit potential condition for pH 12.5 and 13 solutions sodium sulfate concentrations as high as 65000 ppm did not show ability to depassivate steel. Sodium sulfate concentrations as high as 20000 ppm in pH 13 solution did not show indication to destabilize passive film growth but destabilization of passive film growth resulting in severe corrosion occurred in the presence of 20000 ppm sodium sulfate in pH 12.5 solution. Tests in pH 12.5 sulfate solution resulted in active corrosion or localized pitting corrosion. Sulfate levels associated with corrosion development was consistent to ranges reported in the literature. Keywords: Post-Tension Grout Sulfate Deficient Corrosion
Severe corrosion of post-tensioned tendons in Florida bridges utilizing pre-packaged thixotropic grout products were documented. In those cases conventional causes of steel corrosion in tendons were not consistent with corrosion development. Good correlation between the presence of deficient grout corrosion development and enhanced sulfate ion concentrations was observed. An update on laboratory testing of steel wire in sulfate solutions representative of deficient grout pore water is presented. The test setup was made to determine if sulfates in alkaline solutions can depassivate steel or if early presence of sulfates in alkaline solution may provide conditions that would adversely affect stable passive film formation. In the open circuit potential condition for pH 12.5 and 13 solutions sodium sulfate concentrations as high as 65000 ppm did not show ability to depassivate steel. Sodium sulfate concentrations as high as 20000 ppm in pH 13 solution did not show indication to destabilize passive film growth but destabilization of passive film growth resulting in severe corrosion occurred in the presence of 20000 ppm sodium sulfate in pH 12.5 solution. Tests in pH 12.5 sulfate solution resulted in active corrosion or localized pitting corrosion. Sulfate levels associated with corrosion development was consistent to ranges reported in the literature. Keywords: Post-Tension Grout Sulfate Deficient Corrosion
Product tags
Also Purchased
Picture for Molecular Techniques for onsite monitoring of microbial populations in oilfields – Overview Perspec
Available for download

51316-7698-Molecular Techniques for onsite monitoring of microbial populations in oilfields – Overview Perspectives and Evaluation

Product Number: 51316-7698-SG
ISBN: 7698 2016 CP
Author: Renato De Paula
Publication Date: 2016
$20.00
Picture for Localized Top-of-Line Corrosion In Marginally Sour Environments
Available for download

51316-7695-Localized Top-of-Line Corrosion In Marginally Sour Environments

Product Number: 51316-7695-SG
ISBN: 7695 2016 CP
Author: Najmiddin Yaakob
Publication Date: 2016
$20.00
Picture for Localized Corrosion of Corrosion-Resistant Alloys in Oil and Gas Production Environments: II. Corros
Available for download

51316-7708-Localized Corrosion of Corrosion-Resistant Alloys in Oil and Gas Production Environments: II. Corrosion Potential

Product Number: 51316-7708-SG
ISBN: 7708 2016 CP
Author: Andrzej Anderko
Publication Date: 2016
$20.00